Please use this identifier to cite or link to this item: https://hdl.handle.net/11681/12788
Full metadata record
DC FieldValueLanguage
dc.contributorUnited States. Army. Corps of Engineers. Buffalo District-
dc.contributor.authorKrinitzsky, E. L.-
dc.date.accessioned2016-07-06T14:28:01Z-
dc.date.available2016-07-06T14:28:01Z-
dc.date.issued1991-11-
dc.identifier.urihttp://hdl.handle.net/11681/12788-
dc.descriptionTechnical Report-
dc.descriptionAbstract: There were no active faults either at the Eisenhower and Snell Lock sites or in the general area. The locks were determined to be in a seismic hotspot termed the Massena zone. The zone was given a floating earthquake of Modified Mercalli (MM) intensity of VIII which is the threshold of damage to properly built structures. Parameters for a Maximum Credible Earthquake (MCE) were assigned as horizontal peak motions of 0.83 g for acceleration, 35 cm/sec for velocity, and 12.4 sec for duration. The Operating Basis Earthquake (OBE) was assigned 0.46 g, 24 cm/sec, and 8.8 sec, respectively. A set of six accelerograms with response spectra was selected to be used with these parameters.-
dc.publisherGeotechnical Laboratory (U.S.)-
dc.publisherEngineer Research and Development Center (U.S.)-
dc.relationhttp://acwc.sdp.sirsi.net/client/en_US/search/asset/1027705-
dc.relation.ispartofseriesTechnical report (U.S. Army Engineer Waterways Experiment Station) ; GL-91-24.-
dc.rightsApproved for public release; distribution is unlimited.-
dc.sourceThis Digital Resource was created from scans of the Print Resource-
dc.subjectEarthquakes-
dc.subjectEarthquake hazards-
dc.subjectEarthquake ground motions-
dc.subjectEarthquake risk analysis-
dc.subjectMassena, New York-
dc.subjectSaint Lawrence Seaway-
dc.subjectEisenhower and Snell Locks-
dc.subjectHydraulic structures-
dc.subjectDams-
dc.subjectLocks-
dc.subjectSeismology-
dc.subjectGeology-
dc.titleGeological-seismological evaluation of earthquake hazards at Eisenhower and Snell Locks, Saint Lawrence Seaway, Massena, New York-
dc.typeReporten_US