Please use this identifier to cite or link to this item: https://hdl.handle.net/11681/8526
Full metadata record
DC FieldValueLanguage
dc.contributorCold Regions Research and Engineering Laboratory (U.S.)-
dc.contributor.authorBerman, Justin B.-
dc.contributor.authorAl-Chaar, Ghassan K.-
dc.contributor.authorDutta, Piyush K.-
dc.date.accessioned2016-06-20T13:27:30Z-
dc.date.available2016-06-20T13:27:30Z-
dc.date.issued2002-12-
dc.identifier.urihttp://hdl.handle.net/11681/8526-
dc.descriptionTechnical Report-
dc.descriptionAbstract: To facilitate both engineering research and the design of unreinforced masonry (URM) structures, a standardized procedure for testing small-scale brick panel specimens would be beneficial. Some researchers have conducted simple monoaxial shear tests on brick triplet specimens, but these have tended to be unrealistic because they do not account for the effects of normal gravity loads. However, a triplet test that properly accounts for normal loading effects could be as useful to the construction industry as standard concrete cylinder and mortar cube tests. In support of a larger study on URM seismic rehabilitation techniques, the authors developed a triplet shear test that accounts for normal loads. One hundred brick triplets were tested. About one-third were strengthened on one side with fiber-reinforced polymer (FRP) material, and another third were strengthened on two sides. The remaining triplets were not reinforced. Each type of triplet was shear-tested to failure under one of six different percentages of ultimate normal capacity. The results were analyzed, compared and incorporated into the results of the larger study. It is concluded that the triplet test can provide a useful estimate of the shear capacity and failure modes of masonry wall systems in the field.-
dc.publisherConstruction Engineering Research Laboratory (U.S.)-
dc.publisherEngineer Research and Development Center (U.S.)-
dc.relationhttp://acwc.sdp.sirsi.net/client/en_US/search/asset/1002702-
dc.relation.ispartofseriesERDC TR ; 02-7.-
dc.rightsApproved for public release; distribution is unlimited.-
dc.sourceThis Digital Resource was created in Microsoft Word and Adobe Acrobat-
dc.subjectFiber reinforced polymer (FRP)-
dc.subjectComposite materials-
dc.subjectFibrous composites-
dc.subjectStructural engineering-
dc.subjectMasonry-
dc.subjectSeismic testing-
dc.subjectEarthquake resistant design-
dc.titleBiaxial loading and failure behavior of brick triplets with fiber-reinforced polymer composite upgrades-
dc.typeDOCUMENT-
Appears in Collections:Documents

Files in This Item:
File Description SizeFormat 
12114.pdf994.22 kBAdobe PDFThumbnail
View/Open