dc.descriptionTechnical Report-
dc.descriptionAbstract: The physical model investigation of the West Closure Complex (WCC) Pump Station evaluated flow leaving the 1740 cfs pumps through the flowerpot discharge outlet (FPDO). The model study evaluated stability of flow in the FPDO, head loss through the FPDO to use in pump head estimation, downstream riprap stability, and performance of keel coolers both inside the FPDO and downstream of the FPDO in the tailwater. The recommended Type 8 Design FPDO has a 14-in. wide rounded lip with its top located at elevation (el) 14, the chamber floor at el 11, and the roof at el 23. The diameter of the outlet at the top of the semicircular lip at el 14 was 169.5 in. Two 3-ft wide piers at the downstream end of the chamber were found to not have adverse effects on pump head or flow exiting the chamber. Pressures measured in the pump column and dye injections in the flowerpot section showed stable flow conditions in the vertical column above the pump. Water levels in the chamber were well below the roof and should allow air bulking of the flow without filling of the chamber.-
dc.publisherCoastal and Hydraulics Laboratory (U.S.)-
dc.publisherEngineer Research and Development Center (U.S.)-
dc.relationhttp://acwc.sdp.sirsi.net/client/en_US/search/asset/1027640-
dc.relation.ispartofseriesERDC/CHL TR ; 13-3.-
dc.rightsApproved for public release; distribution is unlimited.-
dc.sourceThis Digital Resource was created in Microsoft Word and Adobe Acrobat-
dc.subjectKeel coolers-
dc.subjectHydraulic structures-
dc.subjectPhysical model-
dc.subjectPump diffuser-
dc.subjectPump discharge-
dc.subjectPump head-
dc.subjectPump impeller-
dc.subjectPumps-
dc.subjectRiprap design-
dc.subjectWest Closure Complex, New Orleans, Louisiana-
dc.titlePhysical model study of Flowerpot Discharge Outlet, West Closure Complex, New Orleans, Louisiana-
dc.typeReporten_US
Appears in Collections:Technical Report

Files in This Item:
File Description SizeFormat 
ERDC-CHL-TR-13-3.pdf5.54 MBAdobe PDFThumbnail
View/Open