Please use this identifier to cite or link to this item:
https://hdl.handle.net/11681/5574
Title: | Freezing test for evaluating relative frost susceptibility of various soils |
Authors: | Kaplar, Chester W. |
Keywords: | Frost heave Frost heaving Frost Frost susceptibility tests Frozen soil tests Soil freezing tests Soil freezing Frozen soils Frozen ground Frozen ground mechanics Frost resistance |
Publisher: | Cold Regions Research and Engineering Laboratory (U.S.) Engineer Research and Development Center (U.S.) |
Series/Report no.: | Research report (Cold Regions Research and Engineering Laboratory (U.S.)) ; 250. |
Description: | Technical Report Abstract: This report presents a description of the equipment and procedures used in the laboratory test of the relative frost susceptibility of different soils on Corps of Engineers construction projects and include typical results of freezing tests of natural soils. The test utilizes a slow unidirectional freezing of a 6-in. high, remolded or undisturbed soil specimen with water available at the base (open system). The heaving rate measured during the test is used as the basis for classification of the frost susceptibility potential of the soil. This type of test, which measures heaving rate, is considered most versatile and adaptable for evaluating the effects of numerous soil parameters on frost heave. |
Rights: | Approved for public release; distribution is unlimited. |
URI: | http://hdl.handle.net/11681/5574 |
Appears in Collections: | Technical Report |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
CRREL-Technical-Report-250.pdf | 19.97 MB | Adobe PDF | ![]() View/Open |