Title: Reaeration tests, Enid Lake outlet works
Authors: Hydraulics Laboratory (U.S.)
Environmental and Water Quality Operational Studies (U.S.)
Tate, Charles H.
Keywords: Conduits
Outlet works
Hydraulic structures
Reservoirs
Enid Lake
Mississippi
Radioactive tracers
Gas flow
Dissolved oxygen
Publisher: Environmental Laboratory (U.S.)
Engineer Research and Development Center (U.S.)
Description: Technical Report
Abstract: This study presents the results of gas transfer tests of the outlet structure at Enid Lake, Miss. Radioactive tracers, krypton-85 and tritium, were used to determine the gas transfer characteristics of the outlet structure. The sampling technique isolated the effects of the outlet conduit, the trajectory between the conduit and the tailwater, and the submerged portion of the stilling basin. Dissolved oxygen measurements were taken in the conduit in an attempt supplement the radioactive tracer data.