Please use this identifier to cite or link to this item: https://hdl.handle.net/11681/4500
Title: Reaeration through Gated-Conduit Outlet Works
Authors: Wilhelms, Steven C.
Smith, Dennis R. (Dennis Ray), 1943-
Hydraulics Laboratory (U.S.)
Environmental Laboratory (U.S.)
Keywords: Aeration
Reaeration
Oxygen
Conduits
Temperature
Hydraulic gates
Hydraulic structures
Outlet works
Reservoirs
Publisher: U.S. Army Engineer Waterways Experiment Station
Series/Report no.: Technical Report (U.S. Army Engineer Waterways Experiment Station) ; no. E-81-5
Abstract: Dissolved oxygen and temperature data from twelve Corps of Engineers civil works projects were analyzed relative to oxygen uptake through the project's outlet structure. All the structures examined were similar gated-conduit outlet works. The Energy Dissipation Model (EDM) and Deficit Ratio Model (DRM) were evaluated for use in predicting reaeration through outlet works. Most of the structures reaerated their releases to 80-90 percent of saturation. The EDM appears more appropriate for use with structures than does the DRM.
Description: Technical Report
Gov't Doc #: Technical Report E-81-5
Rights: Approved for public release; distribution is unlimited.
URI: http://hdl.handle.net/11681/4500
Appears in Collections:Technical Report

Files in This Item:
File Description SizeFormat 
Technical Report E-81-5.pdf1.98 MBAdobe PDFThumbnail
View/Open