Please use this identifier to cite or link to this item:
https://hdl.handle.net/11681/4454
Title: | Evaluation of criteria for uniformity of roller-compacted concrete |
Authors: | Repair, Evaluation, Maintenance, and Rehabilitation Research Program (U.S.) Green, Brian H. Neeley, Billy D. Poole, Toy S. |
Keywords: | Concrete Concrete mixers Concrete mixer uniformity Roller-compacted concrete |
Publisher: | Structures Laboratory (U.S.) Engineer Research and Development Center (U.S.) |
Description: | Technical Report Abstract: This report presents the results of a laboratory investigation that was conducted for the purpose of validating mixer-uniformity requirements for roller-compacted concrete. The purpose of the investigation was to verify existing guidance or, if necessary, recommend changes to existing guidance. The investigation included both air-entrained and nonair-entrained concrete. The results indicate that existing guidance is appropriate for Vebe consistency, water content, coarse aggregate content, compressive strength, and air-content determinations. However, the results indicated that existing guidance could be too restrictive for the unit weight of air-free mortar determinations. A recommendation was made to consider revising current guidance on the allowable range for unit weight of air-free motar. |
Rights: | Approved for public release; distribution is unlimited. |
URI: | http://hdl.handle.net/11681/4454 |
Appears in Collections: | Technical Report |