Title: | Evaluation of sludge pump clogging issue for an industrial waste pretreatment plant in the Ceres Industrial Park, Vicksburg, MS |
Authors: | Medina, Victor F. Waisner, Scott A. Wynter, Michelle T. |
Keywords: | Factory and trade waste Centralized industrial waste treatment facilities Pollution Sewage sludge |
Publisher: | Environmental Laboratory (U.S.) Engineer Research and Development Center (U.S.) |
Series/Report no.: | Special Report (Engineer Research and Development Center (U.S.) ) ; no. ERDC/EL SR-18-2 |
Abstract: | Dr. Victor F. Medina conducted a site visit on 12 June 2017 for the evaluation of a sludge pump clogging issue at an industrial waste pretreatment plant in the Ceres Industrial Park, Vicksburg, MS. Escorted by Mr. Pablo Diaz of the Port of Vicksburg, the operating issue was that the sludge pump routinely clogs. The sludge material had accumulated around the ball that serves as the check valve, preventing its operation. The ERDC team offered recommendations based on the site visit to resolve the pump clogging issue. |
Description: | Special Report |
Gov't Doc #: | ERDC/EL SR-18-2 |
Rights: | Approved for Public Release; Distribution is Unlimited |
URI: | http://hdl.handle.net/11681/27280 http://dx.doi.org/10.21079/11681/27280 |
Size: | 22 pages/3.527 Mb |
Types of Materials: | PDF/A |
Appears in Collections: | Special Report |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
ERDC-EL SR-18-2.pdf | 3.61 MB | Adobe PDF | ![]() View/Open |