Title: | Investigation of proprietary admixtures. Report 2, 1977-1978 tests |
Authors: | United States. Army. Office of the Chief of Engineers. Structures Laboratory (U.S.) Saucier, K. L. |
Keywords: | Admixtures Concrete asmixtures Water reducing agents |
Publisher: | Concrete Laboratory (U.S.) Engineer Research and Development Center (U.S.) |
Series/Report no.: | Technical report (U.S. Army Engineer Waterways Experiment Station) ; C-77-1 rept.2. |
Description: | Technical report Abstract: Three high-range water-reducing admixtures for concrete were tested to determine compliance with specification CRD-C 87-78 (Class A or D). One admixture met the requirements when used at a dosage to give 18 per cent water reduction; t he second met the requirements when used at a 12 percent water reduction, but failed to do so when used to achieve a 17 per cent reduction; the third failed to do so when used to achieve a 20 percent water reduction. |