Please use this identifier to cite or link to this item: https://hdl.handle.net/11681/2067
Title: General guard wall design considerations for tow entry and exit
Authors: Park, Howard E.
Keywords: Dams
Designs
Flow
Guard walls
Locks
Navigation
River
Publisher: Coastal and Hydraulics Laboratory (U.S.)
Engineer Research and Development Center (U.S.)
Series/Report no.: Technical note (Coastal and Hydraulics Engineering (U.S.)) ; IX-8.
Description: Technical note
PURPOSE: The objective of this research is to provide design guidance that would allow field engineers to design approach guard walls that are safe and efficient to the users, while being cost effective. The guidance available in EM 1110-2-1611 (Headquarters, U.S. Army Corps of Engineers 1980) and rule-of-thumb guidelines requires approach walls to be fairly long; therefore, the cost of implementing the approach walls can be substantial.
Rights: Approved for public release; distribution is unlimited.
URI: http://hdl.handle.net/11681/2067
Appears in Collections:Technical Note

Files in This Item:
File Description SizeFormat 
CHETN-IX-8.pdf1.93 MBAdobe PDFThumbnail
View/Open