Please use this identifier to cite or link to this item: https://hdl.handle.net/11681/13480
Title: Cache River pumping station south of Mound City, Illinois : hydraulic model investigation
Authors: United States. Army. Corps of Engineers. Memphis District
Rothwell, Edward D.
Fletcher, Bobby P.
Keywords: Cache River Pumping station
Pumping stations
Cache River
Illinois
Sumps
Hydraulic models
Publisher: Hydraulics Laboratory (U.S.)
Engineer Research and Development Center (U.S.)
Series/Report no.: Technical report (U.S. Army Engineer Waterways Experiment Station) ; HL-82-1.
Description: Technical Report
Abstract: A 1:10-scale hydraulic model study was conducted to investigate performance of the original design pumping station sump and, if necessary, develop modifications required to provide satisfactory flow to the pump intakes. Satisfactory sump performance was indicated for all anticipated water-surface elevations with either single or multiple pump operations. Adverse sump performance was not evident until the water surface was lowered 3 ft below the minimum anticipated. The model indicated that the approach wing walls to the sump could be constructed of either sheet piling or concrete as originally designed. The size and extent of approach channel riprap protection required for stability with all anticipated flow conditions were also determined.
Rights: Approved for public release; distribution is unlimited.
URI: http://hdl.handle.net/11681/13480
Appears in Collections:Technical Report

Files in This Item:
File Description SizeFormat 
TR-HL-82-1.pdf3.92 MBAdobe PDFThumbnail
View/Open