Please use this identifier to cite or link to this item: https://hdl.handle.net/11681/13363
Title: Pointe Coupee pumping station sump and outlet structure, Upper Pointe Coupee loop area, Louisiana : hydraulic model investigation
Authors: United States. Army. Corps of Engineers. New Orleans District
Copeland, Ronald R.
Keywords: Hydraulic models
Pumping stations
Riprap
Stilling basins
Hydraulic structures
Sump design
Pointe Coupee
Louisiana
Publisher: Hydraulics Laboratory (U.S.)
Engineer Research and Development Center (U.S.)
Series/Report no.: Technical report (U.S. Army Engineer Waterways Experiment Station) ; HL-83-3.
Description: Technical Report
Abstract: Physical models were used to evaluate the hydraulic performance of the Pointe Coupee pumping station sump and outlet structure. A sump design with umbrellas on the suction bells, converging sidewalls, and horizontal vortex suppressor beams provided satisfactory sump performance for pumps with low submergence. Approach channel modifications were found to have a negligible effect on sump performance. A stilling basin design with baffles and divider walls was developed. Riprap sizes were determined for the outlet channel downstream from the stilling basin. With the recommended designs, satisfactory hydraulic performance was achieved for the entire range of expected discharges, sump water-surface elevations, and tailwaters. A third model study of the Point Coupee siphon was also conducted and reported in WES Technical Report HL-82-21 dated September 1982.
Rights: Approved for public release; distribution is unlimited.
URI: http://hdl.handle.net/11681/13363
Appears in Collections:Technical Report

Files in This Item:
File Description SizeFormat 
TR-HL-83-3.pdf8.55 MBAdobe PDFThumbnail
View/Open