Please use this identifier to cite or link to this item: https://hdl.handle.net/11681/13326
Title: Cypress Avenue Pumping Station : hydraulic model investigation
Authors: United States. Army. Corps of Engineers. Huntington District
Fletcher, Bobby P.
Keywords: Pump intake
Pumping stations
Pump stations
Pumping machinery
Intakes (Hydraulic engineering)
Sump
Submerged vortex
Swirl
Submergence
Vortices
Design
Hydraulic models
Columbus, Ohio
Publisher: Hydraulics Laboratory (U.S.)
Engineer Research and Development Center (U.S.)
Series/Report no.: Technical report (U.S. Army Engineer Waterways Experiment Station) ; HL-94-9.
Description: Technical Report
Abstract: The model study was conducted to evaluate the characteristics of flow in the sump and pump intakes and to develop modifications required for reducing swirl in the flow approaching the pump intake. The three pumps were fitted with formed suction intakes (FSI). The 1:11-scale model indicated the need for a minor modification (baffles in the sump) to reduce current circulation in the sump, thereby reducing swirl in the flow approaching the pump propeller. For all anticipated flow conditions, the recommended sump design will enable the FSIs to deliver stable and evenly distributed flow to the pump propellers.
Rights: Approved for public release; distribution is unlimited.