Please use this identifier to cite or link to this item: https://hdl.handle.net/11681/13208
Title: Formed suction intake approach appurtenance geometry
Authors: Fletcher, Bobby P.
Keywords: Approach flow
Sump
Pump bay
Pumping stations
Intakes
Formed suction intake
Vortices
Pump intake
Design
Construction
Hydraulic structures
Issue Date: Feb-1990
Publisher: Hydraulics Laboratory (U.S.)
Engineer Research and Development Center (U.S.)
Series/Report no.: Technical report (U.S. Army Engineer Waterways Experiment Station) ; HL-90-1.
Description: Technical Report
Abstract: Physical hydraulic model tests were conducted to investigate the hydraulic characteristics of a selected formed suction intake (FSI) design subjected to various hydraulic conditions. A variety of pump bay lengths and widths were evaluated. Hydraulic performance was evaluated by measuring flow distribution, swirl angle, and vortex intensity. Test results revealed that the FSI provided satisfactory flow to the pump with adverse flow in the approach. Test results are presented in dimensionless terms in plots and sketches.
URI: http://hdl.handle.net/11681/13208
Appears in Collections:Technical Report

Files in This Item:
File Description SizeFormat 
TR-HL-90-1.pdf2.96 MBAdobe PDFThumbnail
View/Open