Please use this identifier to cite or link to this item: https://hdl.handle.net/11681/13143
Full metadata record
DC FieldValueLanguage
dc.contributorUnited States. Army. Corps of Engineers. Rock Island District-
dc.contributor.authorCooper, Deborah R.-
dc.date.accessioned2016-07-18T15:21:27Z-
dc.date.available2016-07-18T15:21:27Z-
dc.date.issued1987-10-
dc.identifier.urihttp://hdl.handle.net/11681/13143-
dc.descriptionTechnical Report-
dc.descriptionAbstract: The guard lift gate for the Lockport Lock will be equipped to operate during emergency closure of the lock chamber. This will involve operation under dynamic heads. A 1:24-scale section model of the lock chamber, guard and service gate sills, the guard gate, approach area, and lock chamber was used to study magnitude and frequency of the hydraulic forces acting on the lifting cables and the flow conditions over the gate. Tests indicated that the hydraulic load increased as the exposed gate height increased until the exposed gate height became approximately equal to 60 percent of the pool height. At this point, the hydraulic loads peaked and began to decrease with increasing exposed gate heights. This hydraulic model investigation yielded hydraulic loads less than the calculated hydraulic loads provided by the US Army Engineer District, Rock Island. Although some gate vibrations were indicated, they were random and small compared to the magnitude of the total load.-
dc.publisherHydraulics Laboratory (U.S.)-
dc.publisherEngineer Research and Development Center (U.S.)-
dc.relationhttp://acwc.sdp.sirsi.net/client/en_US/search/asset/1032960-
dc.relation.ispartofseriesTechnical report (U.S. Army Engineer Waterways Experiment Station) ; HL-87-15.-
dc.rightsApproved for public release; distribution is unlimited.-
dc.sourceThis Digital Resource was created from scans of the Print Resource-
dc.subjectDynamic heads-
dc.subjectHydraulic forces-
dc.subjectHydraulic structures-
dc.subjectVertical lift gates-
dc.subjectLocks-
dc.subjectLockport Lock-
dc.subjectIllinois-
dc.subjectIllinois Waterway-
dc.subjectVibrations-
dc.titleLift gate for Lockport Lock, Illinois Waterway : hydraulic model investigation-
dc.typeReporten_US
Appears in Collections:Technical Report

Files in This Item:
File Description SizeFormat 
TR-HL-87-15.pdf3.18 MBAdobe PDFThumbnail
View/Open