Title: Geological-seismological evaluation of earthquake hazards at Prompton and Francis E. Walter Damsites, Pennsylvania
Authors: United States. Army. Corps of Engineers. Philadelphia District
Krinitzsky, E. L.
Keywords: Earthquakes
Earthquake motions
Francis E. Walter Dam
Prompton Dam
Seismic zoning
Geology
Seismology
Geophysics
Pennsylvania
Publisher: Geotechnical Laboratory (U.S.)
Engineer Research and Development Center (U.S.)
Series/Report no.: Technical report (U.S. Army Engineer Waterways Experiment Station) ; GL-86-8.
Description: Technical Report
Abstract: A seismic zoning was developed for eastern Pennsylvania and adjacent states based on the geology and the historic seismicity. Floating earthquakes were assigned to those zones in the absence of identifiable active faults, the Prompton and Francis E. Walter Damsites, motions were far field, MM VI, acceleration 0.12g, velocity 7 cm/sec, and 3 sec bracketed duration ≥ 0.05g. Accelerograms and response spectra appropriate to these parameters were selected.
Rights: Approved for public release; distribution is unlimited.
URI: http://hdl.handle.net/11681/12807
Appears in Collections:Technical Report

Files in This Item:
File Description SizeFormat 
TR-GL-86-8.pdf12.88 MBAdobe PDFThumbnail
View/Open