Please use this identifier to cite or link to this item: https://hdl.handle.net/11681/12223
Full metadata record
DC FieldValueLanguage
dc.contributorScience and Technology Corporation (Hampton, Va.)-
dc.contributorU.S. Army Environmental Center-
dc.contributor.authorParker, L. V. (Louise V.)-
dc.contributor.authorRanney, Thomas A.-
dc.date.accessioned2016-06-20T14:30:35Z-
dc.date.available2016-06-20T14:30:35Z-
dc.date.issued1997-10-
dc.identifier.urihttp://hdl.handle.net/11681/12223-
dc.descriptionSpecial Report-
dc.descriptionAbstract: These studies are the second part of a two-year project that examines decontaminating groundwater sampling devices. In the first year, the efficiency of various decontamination protocols was tested using small test pieces of materials that are commonly used in groundwater sampling devices. Those tests showed that a hot detergent wash and rinse followed by hot air drying (105°C) was the most effective decontamination protocol. In these studies, two groundwater sampling devices, a bailer and a bladder pump, were used to sample groundwater that was contaminated with either trichloroethylene (TCE), munitions, or pesticides. These studies showed that a hot detergent wash and hot water rinse followed by hot air drying is an effective method for decontaminating these sampling devices.-
dc.publisherCold Regions Research & Engineering Laboratory-
dc.publisherEngineer Research and Development Center (U.S.)-
dc.relationhttp://acwc.sdp.sirsi.net/client/en_US/search/asset/1001468-
dc.relation.ispartofseriesSpecial report (Cold Regions Research and Engineering Laboratory (U.S.)) ; 97-25.-
dc.rightsApproved for public release; distribution is unlimited.-
dc.sourceThis Digital Resource was created in Microsoft Word and Adobe Acrobat-
dc.subjectBailers-
dc.subjectDecontamination-
dc.subjectGroundwater-sampling pumps-
dc.subjectCleaning-
dc.subjectWater-
dc.subjectSampling-
dc.subjectEquipment-
dc.subjectMaintenance-
dc.subjectGroundwater sampling devices-
dc.titleDecontaminating groundwater sampling devices-
dc.typeReporten_US
Appears in Collections:Special Report

Files in This Item:
File Description SizeFormat 
SR-97-25.pdf107 kBAdobe PDFThumbnail
View/Open