Please use this identifier to cite or link to this item: https://hdl.handle.net/11681/12221
Title: Time-domain reflectometry of water content in Portland cement concrete
Authors: United States. Federal Aviation Administration.
Korhonen, C. J. (Charles J.)
Janoo, Vincent C.
Berini, Christopher M.
Keywords: Concrete
Dielectric constant
Portland cement concrete
Water content
Moisture content
Time-domain reflectometry
Publisher: Cold Regions Research and Engineering Laboratory (U.S.)
Engineer Research and Development Center (U.S.)
Series/Report no.: Special report (Cold Regions Research and Engineering Laboratory (U.S.)) ; 97-27.
Description: Special Report
Abstract: Time-domain reflectometry is useful for measuring the moisture content of solids. However, little information exists on its use with portland cement concrete. By monitoring the response from TDR sensors embedded in concrete as the concrete dried, we developed a second-order polynomial equation that relates dielectric constant to moisture content. The study is valid for the specific concrete studied.
Rights: Approved for public release; distribution is unlimited.
URI: http://hdl.handle.net/11681/12221
Appears in Collections:Special Report

Files in This Item:
File Description SizeFormat 
SR-97-27.pdf242.38 kBAdobe PDFThumbnail
View/Open