Please use this identifier to cite or link to this item:
https://hdl.handle.net/11681/11891
Title: | CRREL roof moisture survey : Pease AFB, Buildings 33, 116, 122 and 205 |
Authors: | United States. Air Force. Base Civil Engineering Division. 509th Combat Support Group. Korhonen, C. J. (Charles J.) Tobiasson, Wayne. Dudley, T. (Timothy) |
Keywords: | Anomalies Roofing Roofs Roof moisture Built-up roofing Infrared photography Thermogram Insulation Pease Air Force Base, New Hampshire |
Publisher: | Cold Regions Research and Engineering Laboratory (U.S.) Engineer Research and Development Center (U.S.) |
Series/Report no.: | Special report (Cold Regions Research and Engineering Laboratory (U.S.)) ; 77-2. |
Description: | Technical Report Abstract: Four building roofs at Pease AFB were surveyed with a hand-held infrared camera to detect wet insulation. Areas of wet insulation on these roofs were marked with spray paint, and 3-in.-diam core samples of the built-up membrane and insulation were taken to verify wet and dry conditions. Flashing defects are considered responsible for most of the wet insulation uncovered in this survey. Recommendations for maintenance, repair, and replacement were developed from the infrared surveys, core samples and visual examinations. |
Rights: | Approved for public release; distribution is unlimited. |
URI: | http://hdl.handle.net/11681/11891 |
Appears in Collections: | Special Report |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
SR-77-2.pdf | 7.33 MB | Adobe PDF | ![]() View/Open |