Please use this identifier to cite or link to this item: https://hdl.handle.net/11681/11891
Title: CRREL roof moisture survey : Pease AFB, Buildings 33, 116, 122 and 205
Authors: United States. Air Force. Base Civil Engineering Division. 509th Combat Support Group.
Korhonen, C. J. (Charles J.)
Tobiasson, Wayne.
Dudley, T. (Timothy)
Keywords: Anomalies
Roofing
Roofs
Roof moisture
Built-up roofing
Infrared photography
Thermogram
Insulation
Pease Air Force Base, New Hampshire
Publisher: Cold Regions Research and Engineering Laboratory (U.S.)
Engineer Research and Development Center (U.S.)
Series/Report no.: Special report (Cold Regions Research and Engineering Laboratory (U.S.)) ; 77-2.
Description: Technical Report
Abstract: Four building roofs at Pease AFB were surveyed with a hand-held infrared camera to detect wet insulation. Areas of wet insulation on these roofs were marked with spray paint, and 3-in.-diam core samples of the built-up membrane and insulation were taken to verify wet and dry conditions. Flashing defects are considered responsible for most of the wet insulation uncovered in this survey. Recommendations for maintenance, repair, and replacement were developed from the infrared surveys, core samples and visual examinations.
Rights: Approved for public release; distribution is unlimited.
URI: http://hdl.handle.net/11681/11891
Appears in Collections:Special Report

Files in This Item:
File Description SizeFormat 
SR-77-2.pdf7.33 MBAdobe PDFThumbnail
View/Open