Title: | Measurement of forces within the structural frame of DEW line ice cap stations DYE-2 and DYE-3 |
Authors: | United States. Air Force. DEW Systems Office. Tobiasson, Wayne. Ueda, Herbert T. Hine, Gary. |
Keywords: | Cold weather construction Greenland DEW line DYE-2 DYE-3 Early warning radar Ice cap facilities Greenland - construction Radar stations Secondary stresses Structural analysis |
Publisher: | Cold Regions Research and Engineering Laboratory (U.S.) Engineer Research and Development Center (U.S.) |
Series/Report no.: | Special report (Cold Regions Research and Engineering Laboratory (U.S.)) ; 205. |
Description: | Special Report Abstract: Regional straining of the ice cap and differential settlement and tilt of footings has induced secondary loads into the structural frame of these facilities. These loads have been measured using hydraulic cylinders at sway bolt interaction points. The measurements indicate that large secondary loads exist within these facilities. It is recommended that structural components be analysed in detail to assess the influence of the measured loads on the integrity of each structure. |
Rights: | Approved for public release; distribution is unlimited. |