dc.description | Abstract: Samples of Type K shrinkage-compensating cement from all 17 mills producing that cement in 1974 were obtained and evaluated for compliance with a proposed specification for these cements. The cements were also evaluated for specific gravity, fineness, heat of hydration, and expansion and drying shrinkage in mortars. Concretes were also made with the cements and evaluated for air content, slump, compressive strength, expansion, and drying shrinkage. In general most cements had little trouble meeting the specification requirements although a few cements had difficulty meeting the restrained-expansion requirements. The application of the proposed specification called attention to several shortcomings in the specification. Both concretes and mortars made with Type K expansive cements generally had higher compressive strengths than comparably proportioned Type II cement mixtures. Slumps of Type K cement concrete were generally less than the Type II cement control mixture. Observations of air contents in both mortar and concrete suggest that some compatibility problems between certain individual cements and air-entraining agents may exist. The data indicate that the use of Type K cements in a wide variety of different applications should pose no extraordinary problems. | - |
dc.publisher | Concrete Laboratory (U.S.) | - |
dc.publisher | Engineer Research and Development Center (U.S.) | - |
dc.relation | http://acwc.sdp.sirsi.net/client/en_US/search/asset/1043915 | - |
dc.relation.ispartofseries | Miscellaneous paper (U.S. Army Engineer Waterways Experiment Station) ; C-78-2. | - |
dc.rights | Approved for public release; distribution is unlimited. | - |
dc.source | This Digital Resource was created from scans of the Print Resource. | - |
dc.subject | Air content (Concrete) | - |
dc.subject | Air entraining agents | - |
dc.subject | Compressive strength (Concrete) | - |
dc.subject | Concrete drying shrinkage | - |
dc.subject | Expansive cement Type K | - |
dc.subject | Expansive cement concretes | - |
dc.subject | Expansive cements | - |
dc.subject | Mortars (Material) | - |
dc.subject | Shrinkage compensating concretes | - |
dc.subject | Slump tests | - |
dc.subject | Specifications | - |
dc.subject | X-ray diffraction | - |
dc.title | A look at Type K shrinkage-compensating cement production and specifications | - |