Please use this identifier to cite or link to this item:
https://hdl.handle.net/11681/11249
Title: | Strength design of reinforced concrete hydraulic structures. Report 8, Design of buried circular conduits-flexure and shear |
Authors: | Woodson, Stanley C. |
Keywords: | Circular conduits Radial tension Strength Flexure Reinforced concrete design Hydraulic structures Shear Design Specifications Concrete pipes |
Publisher: | Structures Laboratory (U.S.) Engineer Research and Development Center (U.S.) |
Series/Report no.: | Technical report (U.S. Army Engineer Waterways Experiment Station) ; SL-80-4 rept.8. |
Description: | Technical Report Abstract: A strength design (SD) procedure for buried reinforced concrete circular conduits is presented. The procedure is a combination of results produced through recent work sponsored by the Corps of Engineers and recent studies sponsored by the American Concrete Pipe Association. The SD procedure accounts for both flexure and shear in buried circular conduits subjected to the uniform loading conditions of Engineer Manual 1110-2-2902. Expressions are included that account for the effects of concrete compressive strength and radial tension. A criterion for limiting the flexural reinforcement ratio to prevent unacceptable crack width is also included. This organized presentation of the procedure will enable designers to evaluate further the application of recent research to real problems, with the goal of improving the Corps' SD methods. |
Rights: | Approved for public release; distribution is unlimited. |
URI: | http://hdl.handle.net/11681/11249 |
Appears in Collections: | Technical Report |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
TR-SL-80-4-Report-8.pdf | 8.33 MB | Adobe PDF | ![]() View/Open |