Please use this identifier to cite or link to this item: https://hdl.handle.net/11681/11065
Title: Abrasion-erosion evaluation of concrete mixtures for repair of low-flow channel, Los Angeles River
Authors: United States. Army. Corps of Engineers. Los Angeles District.
Holland, Terence C.
Keywords: Channels
Low-flow channel
Los Angeles
California
Hydraulic structures
Repairs
Concrete mix
Concrete additives
Concrete deterioration
Silica fume
Publisher: Structures Laboratory (U.S.)
Engineer Research and Development Center (U.S.)
Series/Report no.: Miscellaneous paper (U.S. Army Engineer Waterways Experiment Station) ; SL-86-12.
Description: Miscellaneous Paper
Abstract: The work described in this report involved abrasion-erosion testing of several concrete mixtures containing silica fume to evaluate the relative potential of the several mixtures to resist such attack. The mixtures were candidates for use in repair work to be conducted by the US Army Engineer District, Los Angeles. Concrete was placed in the field between 21 and 23 September 1983. Conclusions included (1.) the mixtures tested could provide excellent resistance to abrasion-erosion damage; (2.) no more than 15 percent fume should be used; (3.) mixtures were difficult to place and required special attention but were worth the extra effort; and (4.) concretes containing silica fume appear to offer the best resistance to abrasion-erosion damage.
Rights: Approved for public release; distribution is unlimited.
URI: http://hdl.handle.net/11681/11065
Appears in Collections:Miscellaneous Paper

Files in This Item:
File Description SizeFormat 
MP-SL-86-12.pdf14.8 MBAdobe PDFThumbnail
View/Open