Please use this identifier to cite or link to this item: https://hdl.handle.net/11681/10645
Full metadata record
DC FieldValueLanguage
dc.contributorUnited States. Army. Corps of Engineers. St. Paul District-
dc.contributor.authorMcGee, Richard G.-
dc.date.accessioned2016-06-20T14:04:37Z-
dc.date.available2016-06-20T14:04:37Z-
dc.date.issued1983-06-
dc.identifier.urihttp://hdl.handle.net/11681/10645-
dc.descriptionMiscellaneous Paper-
dc.descriptionAbstract: Tests were conducted to obtain data pertaining to the hydraulic performance of the facility and to verify portions of the model study results. The test program measured floor pressure fluctuations directly below the pump intakes, flow distribution in the sump entrance, and pump column vibrations. Data reduction and analysis fndicated small floor pressure fluctuations, generally uniform flow distribution, and insignificant pump column vibrations. In most cases, the prototype test data compared favorably with model findings.-
dc.publisherHydraulics Laboratory (U.S.)-
dc.publisherEngineer Research and Development Center (U.S.)-
dc.relationhttp://acwc.sdp.sirsi.net/client/en_US/search/asset/1034589-
dc.relation.ispartofseriesMiscellaneous paper (U.S. Army Engineer Waterways Experiment Station) ; HL-83-4.-
dc.rightsApproved for public release; distribution is unlimited.-
dc.sourceThis Digital Resource was created from scans of the Print Resource-
dc.subjectFlood control-
dc.subjectFlood prevention-
dc.subjectPumping stations-
dc.subjectPumping tests-
dc.subjectHydraulic structures-
dc.subjectIndian Creek Pumping Station-
dc.subjectMankato-
dc.subjectMinnesota-
dc.titleIndian Creek Pumping Station hydraulic prototype tests, Mankato, Minnesota-
dc.typeReporten_US
Appears in Collections:Miscellaneous Paper

Files in This Item:
File Description SizeFormat 
MP-HL-83-4.pdf6.11 MBAdobe PDFThumbnail
View/Open