Please use this identifier to cite or link to this item: https://hdl.handle.net/11681/10249
Full metadata record
DC FieldValueLanguage
dc.contributorPhiladelphia Naval Shipyard. Environmental, Safety, and Health Office.-
dc.contributor.authorSharp, Michael K.-
dc.contributor.authorOlsen, R. S. (Richard S.)-
dc.contributor.authorKala, Raju V.-
dc.contributor.authorPowell, Jeff F.-
dc.date.accessioned2016-06-20T13:53:42Z-
dc.date.available2016-06-20T13:53:42Z-
dc.date.issued1992-12-
dc.identifier.urihttp://hdl.handle.net/11681/10249-
dc.descriptionMiscellaneous Paper-
dc.descriptionAbstract: This report documents the results of an investigation at the Philadelphia Naval Shipyard, Philadelphia, Pennsylvania. The site was investigated utilizing the Site Characterization and Analysis Penetrometer System, with a fiber optic fluorimeter sensor. This sensor allows the detection of hydrocarbon contaminants in the subsurface. A total of six sites were investigated at the base, at locations that were known or suspected to contain hydrocarbon contaminants. The sensor mounted in a conventional cone penetrometer was able to detect and characterize the contaminants in the vertical and horizontal directions. Of the six sites investigated, five were found to have contaminants. The concentrations at the various sites are reported herein.-
dc.publisherGeotechnical Laboratory (U.S.)-
dc.publisherEngineer Research and Development Center (U.S.)-
dc.relationhttp://acwc.sdp.sirsi.net/client/en_US/search/asset/1041508-
dc.relation.ispartofseriesMiscellaneous paper (U.S. Army Engineer Waterways Experiment Station) ; GL-92-39.-
dc.rightsApproved for public release; distribution is unlimited.-
dc.sourceThis Digital Resource was created from scans of the Print Resource-
dc.subjectCone penetrometer-
dc.subjectGeophysical surveys-
dc.subjectFiber optic sensor-
dc.subjectHydrocarbon contaminants-
dc.subjectTRPH, O&G, aromatics-
dc.subjectSoil surveys-
dc.subjectSoil pollution-
dc.subjectPhiladelphia Naval Shipyard-
dc.subjectPennsylvania-
dc.titleField evaluation of the site characterization and analysis penetrometer system at Philadelphia Naval Shipyard, Philadelphia, Pennsylvania-
dc.typeReporten_US
Appears in Collections:Miscellaneous Paper

Files in This Item:
File Description SizeFormat 
MP-GL-92-39.pdf17.76 MBAdobe PDFThumbnail
View/Open